The calculation, step by step
- Useful heat per year
Heated area × demand from the table × dwelling factor × temperature factor
- Purchased energy per year
Useful heat ÷ seasonal efficiency, or ÷ seasonal COP for a heat pump
- Variable heating cost per year
Purchased energy × your price per kWh
The dwelling factor is 0.72 for an apartment and 1 for a detached house. The temperature factor is max(0.72, 1 + (indoor °C − 21) × 0.07). These are simplified LifeTally assumptions: the apartment factor does not describe every flat, and the temperature adjustment is not a weather or heat-loss model.
Worked example: a 65 m² apartment with a gas boiler
This fixed USD example uses average insulation, a cool winter, 21 °C, efficiency 0.90 and an illustrative gas price of $0.081/kWh. It is separate from your editable result above.
- Useful heat
- 65 × 120 × 0.72 × 1 = 5,616 kWh/year
- Gas energy purchased
- 5,616 ÷ 0.90 = 6,240 kWh/year
- Annual variable cost
- 6,240 × $0.081 = $505.44/year
- Average heating month
- $505.44 ÷ 6 = $84.24
- Average calendar month
- $505.44 ÷ 12 = $42.12
Demand assumptions used by LifeTally
Useful space-heating energy in kWh per m² per year, before the dwelling and temperature factors. These illustrative values are not official building benchmarks or measurements for your country.
Illustrative heat demand, kWh/(m²·year)| Winter scenario | Old / draughty | Average insulation | Modern / efficient |
|---|
| Mild · 4 months | 130 | 80 | 45 |
|---|
| Cool · 6 months | 190 | 120 | 70 |
|---|
| Very cold · 8 months | 260 | 165 | 95 |
|---|
What “per month” means
The headline divides the annual cost across the heating season: mild = 4 months, cool = 6, very cold = 8. It is an average heating month, not the coldest month or an equal monthly payment. Divide the annual result by 12 to budget over the whole calendar year.
Use prices and efficiency on the same basis
- Gas, pellets and direct electric heating
- Enter the price of one kWh of input energy. A seasonal efficiency of 0.90 means 0.90 kWh of useful heat per 1 kWh purchased; enter 0.90, not 90. For a heat pump, use an expected seasonal COP or SPF, not a single laboratory COP measured at one outdoor temperature.
- Gas by m³ or pellets by kg
- Convert the bill to a price per kWh using the supplier’s energy conversion or fuel specification. A price per cubic metre or kilogram cannot be entered directly in this field. Keep the efficiency and fuel-energy basis consistent.
- District heating
- If your tariff already charges per kWh of heat delivered at your meter, use efficiency 1. Only include losses beyond that meter if they apply to your home; counting network losses again would overstate the bill.
What can change the real bill?
The estimate excludes standing charges, fixed service fees, hot water, cooking, installation and maintenance. It also does not model local weather, ventilation, solar gains, adjoining heated rooms, floor position or a heating schedule. Replace the example tariff with your own variable price, including applicable taxes on the same basis as your bill. Selecting a currency does not load a supplier tariff or a live exchange rate.
Questions before you use the result
Can this choose the size of a boiler or heat pump?
No. Annual kWh describe energy over time, while equipment capacity is measured in kW at a design temperature. Sizing needs a room-by-room heat-loss assessment.
Is the insulation saving a renovation quote?
No. It compares your chosen demand with the table’s “Modern / efficient” demand, keeping area, temperature, tariff and system unchanged. It includes neither renovation cost nor achievable site-specific savings, so it is not a payback calculation.
Why is my supplier’s bill different?
Compare the same period and separate space-heating consumption from hot water and other uses. Add fixed charges separately. Real weather, occupancy and system operation can differ substantially from these scenarios.
Which values should I check first?
Check heated area, your actual energy price and a realistic seasonal efficiency or SPF. Treat the demand category as a broad scenario; an energy assessment or separately metered heating history gives stronger evidence for your home.